Industry leaders since '68
Emergency Service: +1(440)708-1770
Gas disinfection equipment
Stocked parts
Quick response

Superior Products representative for Ohio & Western Pennsylvania

Control Associates represents, supplies, and services Superior Products for facilities that rely on gas disinfection, gas feed safety, residual control, and dependable field support.

Product Catalog

The equipment we sell and service most

We carry almost the entire Superior catalog. If you do not see what you need, ask us.
Superior VR-1 vacuum regulator mounted on chlorine cylinder

VR-1 Vacuum Regulator

Direct cylinder-mounted vacuum regulator that opens the chlorine inlet only under system vacuum. The foundation of every manual-feed Superior gas chlorinator from CL-1 through CL-5, and the part operators reach for most often when something needs replacing.

Capacity —Up to 500 lb/day (10 kg/hr)
Spec sheet —chlorinators.com
Superior VR-16 automatic switchover vacuum regulators

VR-16 Automatic Switchover Vacuum Regulator

Auto-switchover vacuum regulator pair with built-in latching detent, the system stays in chlorination service when a cylinder empties, no operator intervention. Round-the-clock chlorination without the 3 a.m. callout.

Capacity —Up to 250 lb/day (5 kg/hr)
Spec sheet —chlorinators.com
Superior rotameter flow meter panel with rate control valve

Rotameter Flow Meter Panels

Variable-area metering tubes with ±2% accuracy and 20:1 turndown across the Superior catalog, manually adjusted, panel-mountable wherever the operator wants visibility, all tubes interchangeable in the field without special tools.

Capacity —0.8 to 500 lb/day metering tubes
Spec sheet —chlorinators.com
Superior EJ-1 ejector installation showing water main connection

EJ-1 Hi/Low Ejector

Water-operated venturi ejector that generates the vacuum driving the whole feed system. Dual-pressure check valve standard, rated to 300 PSIG backpressure with the universal diffuser that hits any solution main without special adaptors.

Capacity —Up to 250 lb/day chlorine
Spec sheet —chlorinators.com
Superior SLD gas leak detector controller

SLD Series Gas Leak Detectors

Chlorine, sulfur dioxide, ammonia, and ozone gas detection with data logging, 95 dB alarm, password-protected event log up to 256 events, NEMA 4X enclosure, and 4–20 mA monitor output for SCADA integration. OSHA-compliant two-level alarms.

Capacity —Sensor range up to 1,000 ft from controller
Spec sheet —chlorinators.com
Superior CL-26 automatic switchover gas chlorinator

CL-26 Automatic Switchover Gas Chlorinator

Full vacuum-operated chlorination system with two auto-switchover regulators, pressure relief/vent valve, flow meter panel, and ejector. Mounts on cylinders, wall manifolds, or ton container adaptors. Built-in latching detent, no manual reset after switchover.

Capacity —Maximum 250 lb/day (5 kg/hr)
Spec sheet —chlorinators.com
Superior CL-55 modular automatic switchover chlorinator

CL-55 Modular Auto-Switchover Chlorinator

Higher-capacity modular automatic switchover system with a wall-mounted switchover module connected to both vacuum regulators. Automatic reset, no operator action after empty cylinder replacement. Up to 500 lb/day chlorine feed.

Capacity —Maximum 500 lb/day (10 kg/hr)
Application —Energy & utilities
Spec sheet —chlorinators.com
Superior CLM-5 manifold-mount chlorinator

CLM-5 Manifold-Mount Chlorinator

Close-coupled vacuum regulator and flow meter as a single cylinder-mounted assembly, separable in the field for remote metering or multi-point chlorination. Titanium external fasteners, fluoroplastic seats, 3-year warranty on the system.

Capacity —Maximum 500 lb/day (10 kg/hr)
Spec sheet —chlorinators.com
Superior NH-1 gas ammoniator

NH-1 Gas Ammoniator

Direct cylinder-mounted ammoniator for chloramination, vacuum-operated solution feed with the same modular regulator / meter / ejector architecture as the chlorinator line. PVDF vacuum fittings standard, stainless inlet adaptor.

Capacity —Up to 100 lb/day NH3 (2,000 g/hr)
Spec sheet —chlorinators.com
Superior NH-15 automatic switchover ammoniator

NH-15 Auto-Switchover Ammoniator

Automatic switchover ammoniation for round-the-clock chloramine without manual reset. Vacuum-operated switchover module, ESD shut-off compatible, and Safe-T-Close integration for emergency cylinder closure.

Capacity —Up to 100 lb/day NH3 (2,000 g/hr)
Spec sheet —chlorinators.com
Superior SD-2 gas sulfonator for dechlorination

SD-2 Gas Sulfonator

Vacuum-operated sulfur dioxide feed for dechlorination, high-impact PVC body, fluoroplastic seats, titanium fasteners. Same yoke-clamp + ceramic filter architecture as the chlorinator line, so spares interchange across families.

Capacity —Maximum 250 lb/day SO2 (5 kg/hr)
Spec sheet —chlorinators.com
Superior SDM-5 modular sulfonator

SDM-5 Modular Sulfonator

Close-coupled regulator and flow meter for sulfur dioxide, modular like the CLM-5 chlorinator, with the option to detach the metering panel for remote applications. Up to 500 lb/day SO2 feed rate.

Capacity —Maximum 500 lb/day SO2 (10 kg/hr)
Spec sheet —chlorinators.com
Superior TCA-1 universal chlorine ton container adaptor

TCA-1 Universal Chlorine Ton Container Adaptor

Adaptor that lets virtually any direct cylinder-mounted gas chlorinator regulator mount onto a U.S. standard ton container, with internal liquid chlorine diverter, 25-watt vaporizer, and 25-micron inlet filter. Plastic-coated for full corrosion isolation.

Capacity —Maximum 500 lb/day (10 kg/hr)
Spec sheet —chlorinators.com
Superior VAS-4 vacuum alarm switch

VAS-4 Vacuum Alarm Switch

Vacuum monitoring for chlorinator users, alerts the team when feed is interrupted or pressure conditions indicate a leak. NEMA 4X fiberglass enclosure, 3-digit LED display, dual alarm relays, 4–20 mA analog output, optional light/horn add-ons.

Capacity —115 VAC / 220 VAC operation
Spec sheet —chlorinators.com
Superior Safe-T-Close STC-1 emergency cylinder shutoff actuator

Safe-T-Close Emergency Shutoff

Battery-backed valve actuator that mounts to the cylinder valve and auto-closes on signal from a gas detector, ESD switch, or SCADA contact. 24 V DC, 50 ft-lb closing torque per Chlorine Institute spec, NEMA 4X controller, supports up to 6 actuators per controller.

Capacity —90°, 180°, or 360° valve rotation
Spec sheet —chlorinators.com
Superior VacuFeed liquid chemical feed system

Superior VacuFeed Liquid Chemical Feed System

Vacuum-operated liquid metering for sodium hypochlorite, calcium hypochlorite, or aqueous ammonia, with the AutoValve closed-loop residual control built in. Triple-bypass check valve, self-priming, automatic timer to clear air binding from bleach lines.

Capacity —Up to 120 gph (420 lph)
Spec sheet —chlorinators.com
What we do

What we do with Superior equipment

Sell, install, service, retrofit, calibrate, and train operators. Our field engineers handle every Superior system across Ohio and Western Pennsylvania.

Service and repair on existing equipment

On-site diagnostics, regulator rebuilds, ejector teardown, and alarm calibration. We bring the system back to spec without replacing it.

New installs and startup

Mount, pipe, vent, and commission a new Superior system end to end. Lead gaskets, vacuum tubing, ejector water assembly, all of it.

Retrofit of existing gas rooms

Swap aging Wallace and Tiernan or Capital Controls equipment to Superior. We reuse existing wall pegs and conduit where possible. Minimum downtime.

Stocked parts and rapid replacement

Vacuum regulator rebuild kits, ejector check valves, metering tubes, lead gaskets, vent screens. On the shelf in Northeast Ohio for same-week dispatch.

Calibration and residual verification

Independent calibration of flow meters, gas detectors, and residual analyzers with documented chain-of-custody reports for Ohio EPA and PA DEP audits.

Operator training and SOP support

Walk-through training for plant staff on Superior equipment, cylinder change procedures, and emergency shutoff drills.

FAQ

Superior Products FAQs

Common questions about Control Associates as your Superior Products rep, parts availability, service area, and retrofits.

Get Started

Quote, service, or parts for your Superior equipment

Tell us about your gas room and what you need. We will get back with a quote, a service slot, or a part number, whichever you asked for.