The DMR Went Digital. The Measurement Did Not.

A decade of work moved NPDES reports from paper to portal. Almost none of it touched the first few feet of the data's journey, from the water to the first number written down.

Control Associates
Control Associates

Key Insight

Electronic reporting made NPDES data faster and more visible. It did nothing for the accuracy of the reading itself. The flume, the probe and the calibration log still decide whether the number on the report is true.

Phase two arrived quietly

On December 21, 2025, the second phase of EPA's NPDES electronic reporting rule came due, without much ceremony. Discharge monitoring reports had already moved online in the first phase, which had a deadline of December 21, 2016. Phase two moved most of the rest: general permit notices, pretreatment program annual reports, sewer overflow and bypass event reports, and several other program reports. In the nine states authorized to run their own biosolids programs, Ohio among them, the annual biosolids report moved too.

EPA's page on the rule lists what it expects in return. Among the benefits are "increasing data accuracy" and "a timelier, complete, more accurate, and nationally-consistent set of data" about the program. Data reported electronically is also made public through EPA's ECHO database. With both phases in place, most paper-based NPDES reporting is now electronic, which is what the rule set out to do.

Note the word accuracy. Then ask what kind of accuracy a portal can deliver. For anyone responsible for NPDES compliance at a treatment plant, that question matters more than the deadline did.

Two kinds of accuracy

The first kind is transcription accuracy: the number on the form matches the number in the logbook. Electronic reporting has done real work here. Values are entered once, checked by software and stored in a form that can be compared month to month. Ohio's system goes a step further. When an eDMR shows what looks like a permit violation, the permittee gets a preliminary compliance report by email the next day.

The second kind is measurement accuracy: the number in the logbook matches the water. Nothing in a portal touches that. A totalizer that reads high produces a clean, on-time, perfectly transcribed report that is wrong by exactly the amount the totalizer is wrong.

The standard for flow has not changed. EPA's NPDES compliance inspection manual tells inspectors that a permittee's flow measurements "should be within 10 percent" of the inspector's, and that a facility must have its flow measurement systems calibrated by a qualified source at least once a year.

Flow carries more weight than it seems to. Every loading on a DMR is a concentration multiplied by a flow, and Ohio's eDMR guidance describes its own loading calculation exactly that way. A flow error does not stay in the flow column. It moves into every load on the report.

The signature has not changed either. In Ohio's eDMR system, the PIN a submitter uses is a legal electronic signature, equivalent to signing in ink. The state's guidance reminds permit holders that they are responsible for making sure the information submitted is, to the best of their knowledge, "true, accurate, and complete." A PIN certifies the number. It cannot certify the flume.

A perfect submission of a wrong number is still a wrong number.

The first few feet

Follow one number from the water to the portal. Effluent passes through a flume. A level sensor above it reads the depth. A transmitter converts depth to flow. A totalizer adds it up. An operator reads the totalizer and writes it down, or a data logger does. Someone enters the value into a spreadsheet, and the spreadsheet feeds the report.

Every hop after the first is now checked by software, or at least by a second set of eyes. The first hop is checked by a person with a ruler, on whatever schedule the plant keeps. If silt has built up in the flume throat, or the sensor has drifted, or the zero was set against the wrong reference years ago, every step downstream preserves the error faithfully. Software can tell you a number is missing or out of range. It cannot tell you a plausible number is wrong.

Errors at the first hop also tend to be steady. A drifted sensor does not produce one bad day. It produces a bad month, and then another, until someone checks. Steady errors are the hardest kind to see in a trend, because the trend looks normal.

Some of the fixes are ordinary. In one flow monitoring case study, the trouble was mechanical floats that kept failing; replacing them with capacitive level switches is what made the reported flow dependable again. No reporting system would have found that. Someone had to look at the instrument.

Visibility changes the stakes a little. Electronically reported data is public and comparable across plants and across years, so an odd flow number is easier for anyone to notice, whether that is a state reviewer, a neighbor or the plant's own engineer. That is probably good news on balance. A measurement problem found early costs less to fix than one found late.

What a trustworthy first number looks like

None of this is exotic. A first number worth reporting has five things behind it:

  • A primary device that has been inspected: the flume or weir clean, level and built to the dimensions its rating assumes.
  • A secondary device, meaning the sensor, transmitter and totalizer, calibrated at least yearly by a qualified source, with the as-found reading recorded before anything is adjusted.
  • A check between calibrations. The inspection manual suggests periodic monthly checks of the flow measurement system, signed by whoever does them.
  • Records kept. Federal permit conditions in 40 CFR 122.41(j)(2) require monitoring records, including calibration and maintenance records and original strip charts, to be kept for at least three years.
  • An alarm on a failed sensor, so a flat line is not reported as a quiet day. That is the kind of job remote telemetry and alarm notification does well.

The pattern behind all five is the same: the check happens at the instrument, on a schedule, and it leaves a record someone else can read.

In Ohio, all of this ends up in the eBusiness Center, through the eDMR service for monitoring data and STREAMS for permit applications and program reports.

The part that did not change

The reporting side of compliance has been modernized, and it was worth doing. The measuring side is still a flume, a probe and a calibration log. That is where this company has spent its time since 1968, and it is where the accuracy of a DMR is actually decided. Electronic reporting asks for the number on time and in the right format. The rest of the job is making sure the number deserved to be sent.

Steve Briggs, Director of Sales Engineering at Control Associates
Do you trust the first number?

Steve can review how your reported values are measured and recorded, from the primary device to the logbook.

Call(440) 708-1770
Emailsteveb@controlassociatesinc.com

Frequently Asked Questions

What is the NPDES eReporting rule?

EPA published the NPDES Electronic Reporting Rule on October 22, 2015. It replaces most paper-based NPDES reporting with electronic reporting, including discharge monitoring reports, general permit notices and other program reports, and it requires states to share NPDES data electronically with EPA.

What changed on December 21, 2025?

Phase 2 came due. Permittees began submitting general permit notices, stormwater certifications and waivers, CAFO and MS4 program reports, pretreatment program annual reports, significant industrial user compliance reports, sewer overflow and bypass event reports and CWA 316(b) annual reports electronically, unless their regulatory authority directed otherwise or they received a waiver. Facilities in states authorized for the biosolids program, Ohio among them, also began submitting biosolids annual reports electronically.

Does electronic reporting make DMR data more accurate?

It reduces transcription and timeliness problems: values are entered once, checked by software and shared in a consistent format. It does not change how the measurement is taken. If a flow meter or sensor reads wrong, the electronic report carries the same error.

How accurate does reported flow need to be?

EPA's NPDES compliance inspection manual tells inspectors that a permittee's flow measurements should be within 10 percent of the inspector's measurements, and that flow measurement systems should be calibrated by a qualified source at least once a year.